For a very good introductory overview article on r value see r values over at the website of.
													
																	Flat roof minimum u value. 
									
	
		
	
																	0 90 1 fiberglass insulation. 
																	You should of course see the manufacturer provided technical data sheet for the r value of specific products. 
																	Floor 0 25 w m2 k. 
																	Roofs 0 20 w m2 k. 
															
													
									
	
		
	
																	Minimum r value state local al alabama 2015 alabama commercial energy code 2 r 25 3 r 25 state local ak alaska 2012 alaska building energy efficiency standard 7 r 35 8 r 35. 
																	Insulation for walls including cavity walls solid walls and timber or steel framed walls. 
																	0 48 1 fiberglass insulation. 
																	Ground floor underfloor heating 0 15w m k. 
															
													
									
	
		
	
																	0 05 8 fiberglass insulation. 
																	Flat metal roof. 
																	Ground floor no underfloor heating 0 18w m k. 
																	Depending on where you live and the part of your home you re insulating walls crawlspace attic etc you ll need a different r value. 
															
													
									
	
		
	
																	Here s a handy r value table that covers most types of roof coverings building insulation and a few other materials. 
																	Walls 0 30 w m2 k. 
																	State applicable energy ashrae zone minimum r value state local ms mississippi ashrae 90 1 2010 2 r 20 3 r 20 state local mo missouri 2012 iecc. 
																	Pitched roof sloping ceilings. 
															
													
									
	
		
	
																	A lower u value indicates better insulation properties hence u value requirements usually specify a maximum value. 
																	Typical recommendations for exterior walls are r 13 to r 23 while r 30 r 38 and r 49 are common for ceilings and attic spaces. 
																	U value of a flat roof. 
																	The current legal limits under building regulations part l are as follows. 
															
													
									
	
		
	
																	The below drawing shows the u value requirements set out for new properties in the building regulations for each element walls floors and roofs. 
																	R value of various materials. 
																	However in new builds u values are part of the overall goal for energy efficiency. 
																	All new projects must prove themselves to be reasonably energy efficient. 
															
													
									
	
		
	
																	Cold roof ceiling level 0 16w m k. 
																	0 11 4 fiberglass insulation. 
																	Insulation for flat roofs pitched roofs and balconies and terraces. 
																	0 26 2 fiberglass insulation. 
															
													
									
	
		
	
																	0 039 12 fiberglass insulation. 
																	Get a u value calculation from our free online u value calculator or our technical department. 
																	0 16 3 fiberglass insulation. 
																	To comply with part l of the building regulations 2010 all roofs to rooms except those in unheated buildings should be thermally insulated to a maximum u value of of 0 18 w m k. 
															
													
									
	
		
	
																	A u value of 0 55 w m k is used for cavity insulation and 0 30 w m k for internal or external wall insulation.